IE FC TP Ground Cable (Type C) 4 x 2, AWG24, Cat6A, sold by the meter, min. 20 m
7.46€
Включая НДС
Артикул: 6XV1878-2G
IE TP ground cable 4x2 Extension ground cable, CAT6A, 8-core, shielded, cable for Connection to IE FC RJ45 plug 4x2, AWG24, Sold by the meter Delivery length max. 1000 m Minimum order 20 m Bus cable for Gigabit-capable cabling system, for permanent installation outdoors and in the ground with an additional PE outer sheath.Time is saved thanks to easy and quick on-site installation. High interference immunity thanks to double shielding. RoHS-compatible and free from varnish-moistening substances. Category 6 (Cat6) of the international cabling standard ISO/IEC 11801 and EN 50173. UL approval Easy length measurement thanks to printed meter marking.
Параметры
UV resistant | - |
Nominal cross section conductor | - |
Core insulation material | Other |
Core identification | Colour |
Flame retardant | No |
Armouring | - |
Circuit integrity | - |
Stranding element | Pairs |
Colour outer sheath | Other |
Category | 6 |
Diameter conductor | 0.51 |
Screen over stranding element | None |
Screen over stranding | Foil + braiding |
Material outer sheath | Polyvinyl chloride (PVC) |
Conductor category | - |
Permitted cable outer temperature during assembling/handling | -40 |
Permitted cable outer temperature after assembling without vibration | -40 |
Number of stranding elements | 4 |
Protective sheath | No |
AWG-size | - |
Number of cores | 8 |
Underground installation | - |
Halogen free (acc. IEC 60754-2) | - |
Insulation integrity in accordance with IEC 60331 | - |
Low smoke (acc. IEC 61034-2) | - |
Stranding | Bundle |
Outer diameter approx. | 10.5 |
Low smoke (acc. EN 61034-2) | Нет |
NVP value | 66 |
Halogen free (acc. EN 60754-1/2) | - |
Oil resistant (acc. EN 60811-404) | - |
Oil resistant (acc. IEC 60811-404) | - |
Conductor surface | Bare |
Longitudinal water blocking cable | - |
Radial water blocking cable | - |
Reaction-to-fire class according to EN 13501-6 | Fca |
Smoke development class according to EN 13501-6 | - |
Euro class flaming droplets/particles according to EN 13501-6 | - |
Euro class acidity according to EN 13501-6 | - |
Min. permitted bending radius, moving application with forced guidance | 84.0 |
Min. permitted bending radius, moving application/free movement | 84.0 |
Min. permitted bending radius, stationary application/permanent installation | 84.0 |
Specification core insulation | - |
Specification material outer sheath | Other |