IE FC TP Trailing Cable GP (Type C) 4 x 2, AWG24/7, Cat6A, sold by the meter, min. 20 m
8.81€
Включая НДС
Артикул: 6XV1878-2C
IE FC TP Trailing Cable GP 4x2 TP installation cable CAT6A AWG 24, for connection to IE FC RJ45 plug 4x 2, AWG24, sold by the meter, delivery length max. 1000 m minimum order 20 m Trailing cable for Gigabit-capable cabling system, for use in cable carriers, e.g. in the case of continuously moving machine parts.Time is saved thanks to easy and quick on-site installation. High interference immunity thanks to double shielding. RoHS-compatible and free from varnish-moistening substances. Category 6 (Cat6) of the international cabling standard ISO/IEC 11801 and EN 50173. UL approval Easy length measurement thanks to printed meter marking.
Параметры
| UV resistant | - |
| Nominal cross section conductor | - |
| Core insulation material | Other |
| Core identification | Colour |
| Flame retardant | No |
| Armouring | - |
| Circuit integrity | - |
| Stranding element | Pairs |
| Colour outer sheath | Green |
| Category | 6 |
| Diameter conductor | 0.58 |
| Screen over stranding element | None |
| Screen over stranding | Foil + braiding |
| Material outer sheath | Polyurethane (PUR) |
| Conductor category | - |
| Permitted cable outer temperature during assembling/handling | -30 |
| Permitted cable outer temperature after assembling without vibration | -30 |
| Number of stranding elements | 4 |
| Protective sheath | No |
| AWG-size | - |
| Number of cores | 8 |
| Underground installation | - |
| Halogen free (acc. IEC 60754-2) | - |
| Insulation integrity in accordance with IEC 60331 | - |
| Low smoke (acc. IEC 61034-2) | - |
| Stranding | Bundle |
| Outer diameter approx. | 8.0 |
| Low smoke (acc. EN 61034-2) | Нет |
| NVP value | 67 |
| Halogen free (acc. EN 60754-1/2) | - |
| Oil resistant (acc. EN 60811-404) | - |
| Oil resistant (acc. IEC 60811-404) | - |
| Conductor surface | Bare |
| Longitudinal water blocking cable | - |
| Radial water blocking cable | - |
| Reaction-to-fire class according to EN 13501-6 | Eca |
| Smoke development class according to EN 13501-6 | - |
| Euro class flaming droplets/particles according to EN 13501-6 | - |
| Euro class acidity according to EN 13501-6 | - |
| Min. permitted bending radius, moving application with forced guidance | 64.0 |
| Min. permitted bending radius, moving application/free movement | 64.0 |
| Min. permitted bending radius, stationary application/permanent installation | 64.0 |
| Specification core insulation | - |
| Specification material outer sheath | Other |