ITP FRNC cable for IE CAT5, 2x2-core, halogen-free installation product, sold by the meter
3.70€
Включая НДС
Артикул: 6XV1851-0AH10
SIMATIC NET, ITP FRNC КАБЕЛЬ ДЛЯ IND. ETHERNET, КАТЕГОРИЯ 5, 2X2 ЖИЛЫ, БЕЗ ГАЛОГЕНА, ПОСТАВКА ПО МЕТРАЖУ ОТРЕЗКАМИ ДЛИНОЙ 20 ... 1000 M For construction of Industrial Twisted Pair (ITP) networks. Due to the double, extra thick shielding, it is very suitable for laying in industrial areas with strong electro-magnetic fields, for example for a connection between control cabinets. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines).Easy installation. Cost effective connection of terminal devices. Data transfer immune to interference due to double shielding with foil and braided shield. Exceeds Category 5 of the ISO/IEC 11801 and EN 50173 international cabling standards.
Параметры
UV resistant | - |
Nominal cross section conductor | 0.33 |
Core insulation material | Other |
Core identification | Colour |
Flame retardant | No |
Armouring | - |
Circuit integrity | - |
Stranding element | Pairs |
Colour outer sheath | Green |
Category | 5 |
Diameter conductor | 0.64 |
Screen over stranding element | Foil |
Screen over stranding | Braiding |
Material outer sheath | Other |
Conductor category | - |
Permitted cable outer temperature during assembling/handling | -25 |
Permitted cable outer temperature after assembling without vibration | -40 |
Number of stranding elements | 2 |
Protective sheath | No |
AWG-size | - |
Number of cores | 4 |
Underground installation | Нет |
Halogen free (acc. IEC 60754-2) | - |
Insulation integrity in accordance with IEC 60331 | - |
Low smoke (acc. IEC 61034-2) | - |
Stranding | Bundle |
Outer diameter approx. | - |
Low smoke (acc. EN 61034-2) | Да |
NVP value | - |
Halogen free (acc. EN 60754-1/2) | - |
Oil resistant (acc. EN 60811-404) | - |
Oil resistant (acc. IEC 60811-404) | - |
Conductor surface | Bare |
Longitudinal water blocking cable | - |
Radial water blocking cable | - |
Reaction-to-fire class according to EN 13501-6 | None |
Smoke development class according to EN 13501-6 | - |
Euro class flaming droplets/particles according to EN 13501-6 | - |
Euro class acidity according to EN 13501-6 | - |
Min. permitted bending radius, moving application with forced guidance | 90.0 |
Min. permitted bending radius, moving application/free movement | 90.0 |
Min. permitted bending radius, stationary application/permanent installation | 90.0 |
Specification core insulation | - |
Specification material outer sheath | Other |