IE FC TP Standard Cable, 50 m
91.80€
Включая НДС
Артикул: 6XV1840-2AN50
IE FC TP Standard Cable GP 2x2 (PROFINET Type A), CAT5E, bus cable 4-wire, shielded special configuration for quick assembly to IE FC RJ45 plug 2x2, 50 m For use in automotive industry, in mechanical engineering (robotics and trailing cable applications), in energy automation, in oil and gas production, and in wind turbines.Time is saved thanks to easy and quick on-site installation. Network immune to interference due to double-shielded cables and integrated grounding concept. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines). Exceeds Category 5 (Cat5e) of the international cabling standards ISO/IEC 11801 and EN 50173. Easy length measurement thanks to printed meter marking.
Параметры
UV resistant | - |
Nominal cross section conductor | - |
Core insulation material | Other |
Core identification | Colour |
Flame retardant | No |
Armouring | Нет |
Circuit integrity | - |
Stranding element | Quad |
Colour outer sheath | Green |
Category | 5E |
Diameter conductor | 0.64 |
Screen over stranding element | None |
Screen over stranding | Foil + braiding |
Material outer sheath | Polyvinyl chloride (PVC) |
Conductor category | - |
Permitted cable outer temperature during assembling/handling | -40 |
Permitted cable outer temperature after assembling without vibration | -40 |
Number of stranding elements | 2 |
Protective sheath | No |
AWG-size | - |
Number of cores | 4 |
Underground installation | Нет |
Halogen free (acc. IEC 60754-2) | - |
Insulation integrity in accordance with IEC 60331 | - |
Low smoke (acc. IEC 61034-2) | - |
Stranding | Bundle |
Outer diameter approx. | 6.5 |
Low smoke (acc. EN 61034-2) | Нет |
NVP value | 66 |
Halogen free (acc. EN 60754-1/2) | - |
Oil resistant (acc. EN 60811-404) | - |
Oil resistant (acc. IEC 60811-404) | - |
Conductor surface | Bare |
Longitudinal water blocking cable | - |
Radial water blocking cable | - |
Reaction-to-fire class according to EN 13501-6 | Eca |
Smoke development class according to EN 13501-6 | - |
Euro class flaming droplets/particles according to EN 13501-6 | - |
Euro class acidity according to EN 13501-6 | - |
Min. permitted bending radius, moving application with forced guidance | 49.0 |
Min. permitted bending radius, moving application/free movement | 49.0 |
Min. permitted bending radius, stationary application/permanent installation | 49.0 |
Specification core insulation | - |
Specification material outer sheath | Other |