PROFIBUS FC Standard Cable IS GP, 2-core, shielded, fast installation, sold by the meter
2.22€
Включая НДС
Артикул: 6XV1831-2A
SIMATIC NET, ССТАНДАРТНЫЙ КАБЕЛЬ PB FC IS GP, ШИННЫЙ ДВУХПРОВОДНЫЙ КАБЕЛЬ ДЛЯ СЕТЕЙ PROFIBUS, ЭКРАНИРОВАННЫЙ, СПЕЦИАЛЬНО ДЛЯ БЫСТРОГО МОНТАЖА, МАКС. ДЛИНА ОТРЕЗКА: 1000 M, МИНИМАЛЬНАЯ: 20 M, ПРОДАЖА ПО МЕТРАЖУ Standard bus cable with special design for quick installation for intrinsically safe distributed I/O systems.Time is saved thanks to easy and quick on-site installation. Reliable shield contact and strain relief as well as efficient EMC shielding. Network is not sensitive to interferences due to shielded, twisted-pair cable. System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals on the bus terminal. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines). Easy length measurement thanks to printed meter marking.
Параметры
UV resistant | - |
Nominal cross section conductor | - |
Core insulation material | Other |
Core identification | Colour |
Flame retardant | No |
Armouring | Нет |
Circuit integrity | - |
Stranding element | Pairs |
Colour outer sheath | Blue |
Category | Other |
Diameter conductor | 0.64 |
Screen over stranding element | None |
Screen over stranding | Foil + braiding |
Material outer sheath | Polyvinyl chloride (PVC) |
Conductor category | - |
Permitted cable outer temperature during assembling/handling | -40 |
Permitted cable outer temperature after assembling without vibration | -40 |
Number of stranding elements | 1 |
Protective sheath | No |
AWG-size | - |
Number of cores | 2 |
Underground installation | Нет |
Halogen free (acc. IEC 60754-2) | - |
Insulation integrity in accordance with IEC 60331 | - |
Low smoke (acc. IEC 61034-2) | - |
Stranding | Bundle |
Outer diameter approx. | 8.0 |
Low smoke (acc. EN 61034-2) | Нет |
NVP value | - |
Halogen free (acc. EN 60754-1/2) | - |
Oil resistant (acc. EN 60811-404) | - |
Oil resistant (acc. IEC 60811-404) | - |
Conductor surface | Bare |
Longitudinal water blocking cable | - |
Radial water blocking cable | - |
Reaction-to-fire class according to EN 13501-6 | Eca |
Smoke development class according to EN 13501-6 | - |
Euro class flaming droplets/particles according to EN 13501-6 | - |
Euro class acidity according to EN 13501-6 | - |
Min. permitted bending radius, moving application with forced guidance | 75.0 |
Min. permitted bending radius, moving application/free movement | 75.0 |
Min. permitted bending radius, stationary application/permanent installation | 75.0 |
Specification core insulation | - |
Specification material outer sheath | Other |