PROFIBUS FC Underground Cable, underground cable 2-core, shielded, sold by the meter
2.84€
Включая НДС
Артикул: 6XV1830-3FH10
SIMATIC NET, PROFIBUS КАБЕЛЬ ДЛЯ БЫСТРОГО МОНТАЖА (FC), 2-ЖИЛЬНЫЙ, ЭКРАНИРОВАННЫЙ, ДЛЯ ПРОКЛАДКИ В ЗЕМЛЕ, ПОСТАВКА ПО МЕТРАЖУ ОТРЕЗКАМИ ДЛИНОЙ 20 … 1000 М Bus cable specially designed for fast installation. For permanent installation in the ground with an additional black outer sheath.Time is saved thanks to easy and quick on-site installation. Reliable shield contact and strain relief as well as efficient EMC shielding. Network is not sensitive to interferences due to shielded, twisted-pair cable. System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals on the bus terminal. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines). Easy length measurement thanks to printed meter marking.
Параметры
| UV resistant | - |
| Nominal cross section conductor | - |
| Core insulation material | Other |
| Core identification | Colour |
| Flame retardant | No |
| Armouring | Да |
| Circuit integrity | - |
| Stranding element | Pairs |
| Colour outer sheath | Black |
| Category | Other |
| Diameter conductor | 0.65 |
| Screen over stranding element | None |
| Screen over stranding | Foil + braiding |
| Material outer sheath | Polyvinyl chloride (PVC) |
| Conductor category | - |
| Permitted cable outer temperature during assembling/handling | -40 |
| Permitted cable outer temperature after assembling without vibration | -40 |
| Number of stranding elements | 1 |
| Protective sheath | No |
| AWG-size | - |
| Number of cores | 2 |
| Underground installation | Да |
| Halogen free (acc. IEC 60754-2) | - |
| Insulation integrity in accordance with IEC 60331 | - |
| Low smoke (acc. IEC 61034-2) | - |
| Stranding | Bundle |
| Outer diameter approx. | 10.8 |
| Low smoke (acc. EN 61034-2) | Нет |
| NVP value | - |
| Halogen free (acc. EN 60754-1/2) | - |
| Oil resistant (acc. EN 60811-404) | - |
| Oil resistant (acc. IEC 60811-404) | - |
| Conductor surface | Bare |
| Longitudinal water blocking cable | - |
| Radial water blocking cable | - |
| Reaction-to-fire class according to EN 13501-6 | Fca |
| Smoke development class according to EN 13501-6 | - |
| Euro class flaming droplets/particles according to EN 13501-6 | - |
| Euro class acidity according to EN 13501-6 | - |
| Min. permitted bending radius, moving application with forced guidance | 81.0 |
| Min. permitted bending radius, moving application/free movement | 81.0 |
| Min. permitted bending radius, stationary application/permanent installation | 81.0 |
| Specification core insulation | - |
| Specification material outer sheath | Other |