PROFIBUS FC Standard Cable, 2-core, special design for fast installation 50 m
84.46€
Включая НДС
Артикул: 6XV1830-0EN50
SIMATIC NET, СТАНДАРТНЫЙ ЭКРАНИРОВАННЫЙ PROFIBUS КАБЕЛЬ ДЛЯ БЫСТРОГО МОНТАЖА (FC), ОТРЕЗОК ДЛИНОЙ 50 M Standard bus cable specially designed for fast installation. The double shield makes it especially suitable for routing through industrial areas with strong electromagnetic fields.Time is saved thanks to easy and quick on-site installation. Reliable shield contact and strain relief as well as efficient EMC shielding. Network is not sensitive to interferences due to shielded, twisted-pair cable. System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals on the bus terminal. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines). Easy length measurement thanks to printed meter marking.
Параметры
UV resistant | - |
Nominal cross section conductor | - |
Core insulation material | Other |
Core identification | Colour |
Flame retardant | No |
Armouring | Нет |
Circuit integrity | - |
Stranding element | Pairs |
Colour outer sheath | Other |
Category | Other |
Diameter conductor | 0.65 |
Screen over stranding element | None |
Screen over stranding | Foil + braiding |
Material outer sheath | Polyvinyl chloride (PVC) |
Conductor category | - |
Permitted cable outer temperature during assembling/handling | -40 |
Permitted cable outer temperature after assembling without vibration | -40 |
Number of stranding elements | 1 |
Protective sheath | No |
AWG-size | - |
Number of cores | 2 |
Underground installation | Нет |
Halogen free (acc. IEC 60754-2) | - |
Insulation integrity in accordance with IEC 60331 | - |
Low smoke (acc. IEC 61034-2) | - |
Stranding | Bundle |
Outer diameter approx. | 8.0 |
Low smoke (acc. EN 61034-2) | Нет |
NVP value | - |
Halogen free (acc. EN 60754-1/2) | - |
Oil resistant (acc. EN 60811-404) | - |
Oil resistant (acc. IEC 60811-404) | - |
Conductor surface | Bare |
Longitudinal water blocking cable | - |
Radial water blocking cable | - |
Reaction-to-fire class according to EN 13501-6 | Eca |
Smoke development class according to EN 13501-6 | - |
Euro class flaming droplets/particles according to EN 13501-6 | - |
Euro class acidity according to EN 13501-6 | - |
Min. permitted bending radius, moving application with forced guidance | 75.0 |
Min. permitted bending radius, moving application/free movement | 75.0 |
Min. permitted bending radius, stationary application/permanent installation | 75.0 |
Specification core insulation | - |
Specification material outer sheath | Other |