PROFIBUS FC Standard Cable, 2-core, special design for fast installation 50 m

PROFIBUS FC Standard Cable, 2-core, special design for fast installation 50 m. 6XV18300EN50
84.46€
Включая НДС
Артикул: 6XV1830-0EN50
SIMATIC NET, СТАНДАРТНЫЙ ЭКРАНИРОВАННЫЙ PROFIBUS КАБЕЛЬ ДЛЯ БЫСТРОГО МОНТАЖА (FC), ОТРЕЗОК ДЛИНОЙ 50 M Standard bus cable specially designed for fast installation. The double shield makes it especially suitable for routing through industrial areas with strong electromagnetic fields.Time is saved thanks to easy and quick on-site installation. Reliable shield contact and strain relief as well as efficient EMC shielding. Network is not sensitive to interferences due to shielded, twisted-pair cable. System-wide grounding concept can be implemented using the external shield of the bus cable and the grounding terminals on the bus terminal. Silicone-free, therefore suitable for use in the automotive industry (for example on paint lines). Easy length measurement thanks to printed meter marking.

Параметры

UV resistant -
Nominal cross section conductor -
Core insulation material Other
Core identification Colour
Flame retardant No
Armouring Нет
Circuit integrity -
Stranding element Pairs
Colour outer sheath Other
Category Other
Diameter conductor 0.65
Screen over stranding element None
Screen over stranding Foil + braiding
Material outer sheath Polyvinyl chloride (PVC)
Conductor category -
Permitted cable outer temperature during assembling/handling -40
Permitted cable outer temperature after assembling without vibration -40
Number of stranding elements 1
Protective sheath No
AWG-size -
Number of cores 2
Underground installation Нет
Halogen free (acc. IEC 60754-2) -
Insulation integrity in accordance with IEC 60331 -
Low smoke (acc. IEC 61034-2) -
Stranding Bundle
Outer diameter approx. 8.0
Low smoke (acc. EN 61034-2) Нет
NVP value -
Halogen free (acc. EN 60754-1/2) -
Oil resistant (acc. EN 60811-404) -
Oil resistant (acc. IEC 60811-404) -
Conductor surface Bare
Longitudinal water blocking cable -
Radial water blocking cable -
Reaction-to-fire class according to EN 13501-6 Eca
Smoke development class according to EN 13501-6 -
Euro class flaming droplets/particles according to EN 13501-6 -
Euro class acidity according to EN 13501-6 -
Min. permitted bending radius, moving application with forced guidance 75.0
Min. permitted bending radius, moving application/free movement 75.0
Min. permitted bending radius, stationary application/permanent installation 75.0
Specification core insulation -
Specification material outer sheath Other