SINAMICS G120D МОДУЛЬ УПРАВЛЕНИЯ CU240D-2 PN PROFINET, STO ON-BOARD 6 DI/1 F-DI, 2 DO, 2 AI USB ИНТЕРФЕЙС SD/MMC-ИНТЕРФЕЙС HTL-ИНТЕРФЕЙС ДАТЧИКА ЗАЩИТА IP65 ОКРУЖ. ТЕМП. -10 ДО +50 ГРАД. С БЕЗ СИЛОВОГО МОДУЛЯ SINAMICS CU240D-2 Control Unit for the SINAMICS G120D distributed inverter. The Control Unit performs closed-loop control functions for the inverter. In addition to the closed-loop control, it has additional functions that can be adapted to the particular application through parameterization. The CU240D‑2 Control Units supersede the CU240D Control Units, whereby both versions can be operated with PM250D Power Modules. The Control Units are available in different versions, for example, in CU240D-2 DP, CU240D-2 DP-F, CU240D-2 PN, CU240D-2 PN-F, CU240D-2 PN-F PP (Push Pull: Alternative connection method for the 24 V DC supply voltage and the PN communication) and CU240D-2 PN-F FO (Fiber Optic). The safety function Safe Torque Off (STO) is already integrated into the standard versions of the CU240D‑2 series (CU240D‑2 DP and CU240D‑2 PN). It can be activated either via PROFIsafe or via the safety input. With the fail-safe variants of the CU240D‑2 series (CU240D‑2 DP‑F xx and CU240D‑2 PN‑F xx), the fail-safe SINAMICS G120D inverter provides five safety functions: Safe Torque Off (STO) to prevent the drive from performing active movements, Safe Stop 1 (SS1) for continuous monitoring of a safe braking ramp, Safely Limited Speed (SLS) for preventing dangerous movements when exceeding a speed limit, Safe Direction (SDI) and Safe Speed Monitoring (SSM). An external 24 V DC power supply is required in order to operate the Control Unit. SINAMICS – the integrated drive family for every field of application.

Параметры

Width 153.0
Height 208.0
Depth 55.0
With control unit -
Number of digital inputs 6
Number of digital outputs 2
Number of analogue inputs 2
Number of analogue outputs -
Supporting protocol for LON Нет
Number of HW-interfaces industrial Ethernet 2
Number of HW-interfaces RS-232 0
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 1
Number of HW-interfaces parallel 11
Number of HW-interfaces other 0
With optical interface Да
Supporting protocol for TCP/IP Нет
Supporting protocol for ASI Нет
Supporting protocol for PROFIBUS Нет
Supporting protocol for CAN Нет
Supporting protocol for INTERBUS Нет
Supporting protocol for KNX Нет
Supporting protocol for MODBUS Нет
Supporting protocol for Data-Highway Нет
Supporting protocol for DeviceNet Нет
Supporting protocol for SUCONET Нет
Supporting protocol for other bus systems Нет
Degree of protection (IP) IP65
With PC connection Да
Supporting protocol for SERCOS Нет
Supporting protocol for INTERBUS-Safety Нет
Mains voltage -
Mains frequency -99999
4-quadrant operation possible -
Number of interfaces PROFINET 2
Type of converter -
Number of phases output -
Number of phases input -
Integrated breaking resistance -
Application in industrial area permitted Да
Application in domestic- and commercial area permitted Нет
Max. output frequency -
Max. output at linear load at rated output voltage -
Max. output at quadratic load at rated output voltage -
Relative symmetric net voltage tolerance -
Relative symmetric net frequency tolerance -
Supporting protocol for AS-Interface Safety at Work Нет
Supporting protocol for DeviceNet Safety Нет
Supporting protocol for EtherNet/IP Да
Supporting protocol for Foundation Fieldbus Нет
Supporting protocol for PROFINET CBA Нет
Supporting protocol for PROFINET IO Да
Supporting protocol for PROFIsafe Да
Supporting protocol for SafetyBUS p Нет
Max. output voltage -
Nominal output current I2N -
Supporting protocol for BACnet -
Degree of protection (NEMA) -