SINAMICS G120D СИЛОВОЙ МОДУЛЬ PM250D ВСТРОЕННЫЙ ФИЛЬТР КЛАССА А, ВОЗМОЖНА РЕКУПЕРАЦИЯ 3-ФАЗН.380-480 В +10/-10% 47-63 ГЦ ВЫСОКИЙ УРОВЕНЬ ПЕРЕГРУЗКИ: 5,5 КВТ ПРИ 200% 3С,150% 60С,100% 300С ТЕМП. ОКР. СРЕДЫ: ОТ -10 ДО +55 ГРАД. C 210 X 450 X 145 (ВХШХГ), ТИ SINAMICS PM250D Power Module for the SINAMICS G120D distributed inverter. The regenerative feedback capability of the PM250D Power Module in generating mode (electronic braking) means that energy is returned to the supply system and is not converted into heat in a braking resistor. This saves space, time-consuming dimensioning of the braking resistor as well as its wiring. Generated heat is also reduced. An innovative circuit design reduces the supply harmonics. A line reactor is no longer required, which saves space and costs for engineering and procurement. Further, the PM250D Power Module is suitable for use in safety-related applications, in conjunction with a fail-safe control unit, the drive can be turned into a Safety Integrated Drive. SINAMICS PM250D Power Modules are available in the frame sizes FSA to FSC, in a three-phase voltage range between 380 V and 500V, and in a performance range between 0.75 kW and 7.5 kW. These PM250D Power Modules with integrated line filter class A are suitable for connection to TN and TT supply systems. SINAMICS – the integrated drive family for every field of application.
Параметры
Width | 445.0 |
Height | 210.0 |
Depth | 220.0 |
With control unit | - |
Number of digital inputs | - |
Number of digital outputs | - |
Number of analogue inputs | - |
Number of analogue outputs | - |
Supporting protocol for LON | - |
Number of HW-interfaces industrial Ethernet | - |
Number of HW-interfaces RS-232 | - |
Number of HW-interfaces RS-422 | - |
Number of HW-interfaces RS-485 | - |
Number of HW-interfaces serial TTY | - |
Number of HW-interfaces USB | - |
Number of HW-interfaces parallel | - |
Number of HW-interfaces other | - |
With optical interface | - |
Supporting protocol for TCP/IP | - |
Supporting protocol for ASI | - |
Supporting protocol for PROFIBUS | - |
Supporting protocol for CAN | - |
Supporting protocol for INTERBUS | - |
Supporting protocol for KNX | - |
Supporting protocol for MODBUS | - |
Supporting protocol for Data-Highway | - |
Supporting protocol for DeviceNet | - |
Supporting protocol for SUCONET | - |
Supporting protocol for other bus systems | - |
Degree of protection (IP) | IP65 |
With PC connection | - |
Supporting protocol for SERCOS | - |
Supporting protocol for INTERBUS-Safety | - |
Mains voltage | 380 |
Mains frequency | 50/60 Hz |
4-quadrant operation possible | Да |
Number of interfaces PROFINET | - |
Type of converter | U converter |
Number of phases output | 3 |
Number of phases input | 3 |
Integrated breaking resistance | Да |
Application in industrial area permitted | Да |
Application in domestic- and commercial area permitted | Нет |
Max. output frequency | 650 |
Max. output at linear load at rated output voltage | 5.5 |
Max. output at quadratic load at rated output voltage | 5.5 |
Relative symmetric net voltage tolerance | -10 |
Relative symmetric net frequency tolerance | 10 |
Supporting protocol for AS-Interface Safety at Work | - |
Supporting protocol for DeviceNet Safety | - |
Supporting protocol for EtherNet/IP | - |
Supporting protocol for Foundation Fieldbus | - |
Supporting protocol for PROFINET CBA | - |
Supporting protocol for PROFINET IO | - |
Supporting protocol for PROFIsafe | - |
Supporting protocol for SafetyBUS p | - |
Max. output voltage | - |
Nominal output current I2N | 13.2 |
Supporting protocol for BACnet | - |
Degree of protection (NEMA) | - |