SINAMICS G110M, IP66, FSB, A, 3 AC 380-480 V, 3,00 kW
944.95€
                                                            Включая НДС
                                                        Артикул: 6SL3517-1BE17-7AM0
                                                        
                                SINAMICS G110M POWER MODULE PM240M WITH BUILT IN CL. A FILTER PROTECTION IP65 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 3КВТ FOR 200% 3S,150% 57S,100% 240S SD/MMC-INTERFACE AMBIENT TEMP -10 TO +55 DEG C 135 X 181 X 309 (HXWXD), FSB WITHOUT CONTROL UNIT SINAMICS PM240M Power Module for the SINAMICS G110M distributed inverter. The PM240M Power Modules are suitable for safety-related applications. In conjunction with the CU240M Control Unit, the drive can be turned into a Safety Integrated drive. SINAMICS PM240M Power Modules are available in the frame sizes FSA to FSC, in a three-phase voltage range between 380 V and 480V, and in a performance range between 0.37 kW and 4 kW. These PM240M Power Modules with integrated line filter class A are suitable for connection to TN and TT supply systems. SINAMICS – the integrated drive family for every field of application.
                            
                            Параметры
| Width | 181.0 | 
| Height | 135.0 | 
| Depth | 309.0 | 
| With control unit | - | 
| Number of digital inputs | - | 
| Number of digital outputs | - | 
| Number of analogue inputs | - | 
| Number of analogue outputs | - | 
| Supporting protocol for LON | - | 
| Number of HW-interfaces industrial Ethernet | - | 
| Number of HW-interfaces RS-232 | - | 
| Number of HW-interfaces RS-422 | - | 
| Number of HW-interfaces RS-485 | - | 
| Number of HW-interfaces serial TTY | - | 
| Number of HW-interfaces USB | - | 
| Number of HW-interfaces parallel | - | 
| Number of HW-interfaces other | - | 
| With optical interface | - | 
| Supporting protocol for TCP/IP | - | 
| Supporting protocol for ASI | - | 
| Supporting protocol for PROFIBUS | - | 
| Supporting protocol for CAN | - | 
| Supporting protocol for INTERBUS | - | 
| Supporting protocol for KNX | - | 
| Supporting protocol for MODBUS | - | 
| Supporting protocol for Data-Highway | - | 
| Supporting protocol for DeviceNet | - | 
| Supporting protocol for SUCONET | - | 
| Supporting protocol for other bus systems | - | 
| Degree of protection (IP) | IP66 | 
| With PC connection | - | 
| Supporting protocol for SERCOS | - | 
| Supporting protocol for INTERBUS-Safety | - | 
| Mains voltage | 380 | 
| Mains frequency | 50/60 Hz | 
| 4-quadrant operation possible | - | 
| Number of interfaces PROFINET | - | 
| Type of converter | - | 
| Number of phases output | 3 | 
| Number of phases input | 3 | 
| Integrated breaking resistance | - | 
| Application in industrial area permitted | - | 
| Application in domestic- and commercial area permitted | - | 
| Max. output frequency | 550 | 
| Max. output at linear load at rated output voltage | 3.0 | 
| Max. output at quadratic load at rated output voltage | - | 
| Relative symmetric net voltage tolerance | -10 | 
| Relative symmetric net frequency tolerance | - | 
| Supporting protocol for AS-Interface Safety at Work | - | 
| Supporting protocol for DeviceNet Safety | - | 
| Supporting protocol for EtherNet/IP | - | 
| Supporting protocol for Foundation Fieldbus | - | 
| Supporting protocol for PROFINET CBA | - | 
| Supporting protocol for PROFINET IO | - | 
| Supporting protocol for PROFIsafe | - | 
| Supporting protocol for SafetyBUS p | - | 
| Max. output voltage | - | 
| Nominal output current I2N | - | 
| Supporting protocol for BACnet | - | 
| Degree of protection (NEMA) | - | 