SINAMICS G110M, IP66, FSA, A, 3 AC 380-480 V, 0,37 kW
374.88€
Включая НДС
Артикул: 6SL3517-1BE11-3AM0
SINAMICS G110M POWER MODULE PM240M WITH BUILT IN CL. A FILTER PROTECTION IP65 3AC380-480V +10/-10% 47-63HZ OUTPUT HIGH OVERLOAD: 0,37КВТ FOR 200% 3S,150% 57S,100% 240S SD/MMC-INTERFACE AMBIENT TEMP -10 TO +55 DEG C 135 X 161 X 270 (HXWXD), FSA WITHOUT CONTROL UNIT SINAMICS PM240M Power Module for the SINAMICS G110M distributed inverter. The PM240M Power Modules are suitable for safety-related applications. In conjunction with the CU240M Control Unit, the drive can be turned into a Safety Integrated drive. SINAMICS PM240M Power Modules are available in the frame sizes FSA to FSC, in a three-phase voltage range between 380 V and 480V, and in a performance range between 0.37 kW and 4 kW. These PM240M Power Modules with integrated line filter class A are suitable for connection to TN and TT supply systems. SINAMICS – the integrated drive family for every field of application.
Параметры
Width | 161.0 |
Height | 135.0 |
Depth | 270.0 |
With control unit | - |
Number of digital inputs | - |
Number of digital outputs | - |
Number of analogue inputs | - |
Number of analogue outputs | - |
Supporting protocol for LON | - |
Number of HW-interfaces industrial Ethernet | - |
Number of HW-interfaces RS-232 | - |
Number of HW-interfaces RS-422 | - |
Number of HW-interfaces RS-485 | - |
Number of HW-interfaces serial TTY | - |
Number of HW-interfaces USB | - |
Number of HW-interfaces parallel | - |
Number of HW-interfaces other | - |
With optical interface | - |
Supporting protocol for TCP/IP | - |
Supporting protocol for ASI | - |
Supporting protocol for PROFIBUS | - |
Supporting protocol for CAN | - |
Supporting protocol for INTERBUS | - |
Supporting protocol for KNX | - |
Supporting protocol for MODBUS | - |
Supporting protocol for Data-Highway | - |
Supporting protocol for DeviceNet | - |
Supporting protocol for SUCONET | - |
Supporting protocol for other bus systems | - |
Degree of protection (IP) | IP66 |
With PC connection | - |
Supporting protocol for SERCOS | - |
Supporting protocol for INTERBUS-Safety | - |
Mains voltage | 380 |
Mains frequency | 50/60 Hz |
4-quadrant operation possible | - |
Number of interfaces PROFINET | - |
Type of converter | - |
Number of phases output | 3 |
Number of phases input | 3 |
Integrated breaking resistance | - |
Application in industrial area permitted | - |
Application in domestic- and commercial area permitted | - |
Max. output frequency | 550 |
Max. output at linear load at rated output voltage | 0.37 |
Max. output at quadratic load at rated output voltage | - |
Relative symmetric net voltage tolerance | -10 |
Relative symmetric net frequency tolerance | - |
Supporting protocol for AS-Interface Safety at Work | - |
Supporting protocol for DeviceNet Safety | - |
Supporting protocol for EtherNet/IP | - |
Supporting protocol for Foundation Fieldbus | - |
Supporting protocol for PROFINET CBA | - |
Supporting protocol for PROFINET IO | - |
Supporting protocol for PROFIsafe | - |
Supporting protocol for SafetyBUS p | - |
Max. output voltage | - |
Nominal output current I2N | - |
Supporting protocol for BACnet | - |
Degree of protection (NEMA) | - |