SINAMICS G110D, IP65 / UL type 3, FSC, A, 3 AC 380-500 V, 7,50 kW

SINAMICS G110D, IP65 / UL type 3, FSC, A, 3 AC 380-500 V, 7,50 kW. 6SL35110PE275AM0
2 615.32€
Включая НДС
Артикул: 6SL3511-0PE27-5AM0
SINAMICS G110D ПРИВОД ПЕР. ТОКА С РЕМОНТНЫМ ВЫКЛЮЧАТЕЛЕМ, СО ВСТРОЕННЫМ ФИЛЬТРОМ КЛАССА А, СО ВСТРОЕННЫМ ТОРМОЗНЫМ МОДУЛЕМ, С ШИННЫМ ИНТЕРФЕЙСОМ AS 3-ФАЗН.380-500В +10/-10% 47-63 ГЦ ВЫСОКИЙ УРОВЕНЬ ПЕРЕГРУЗКИ: 7,5 КВТ ПРИ 200% 3С,150% 60С,100% 300С ТЕМП. SINAMICS G110D is the distributed inverter for basic applications for the open-loop and closed-loop control of induction motors in a wide range of industrial applications. The SINAMICS G110D frequency inverter series is the solution for basic drive tasks, especially in the field of conveyor systems. The inverter allows the speed of three-phase asynchronous (induction) motors to be continually controlled and fulfills the requirements of conveyor-related applications with open-loop frequency control. It can be optimally integrated into the system thanks to its compact and low-profile design in an IP65 degree of protection. It can be optimally integrated into the Siemens TIA world of automation via AS-Interface. Further, the simple commissioning and maintenance as a result of the same, standard plug-in connections of the bus, power and I/O connections (ISO23570) for the complete range of power ratings is advantageous. In addition, the modular drive solution and thus standardized, individually tested mechatronics elements and the avoidance of long motor cables between inverter and motor are key features of distributed drive technology. The omission of the control cabinet (thus reduced space and cooling requirements) and the possibility of large spatial extension in conveyor technology are further important features. The SINAMICS G110D is available in a three-phase voltage range between 380 V and 500V, in a performance range between 0.75 kW and 7.5 kW and in the frame sizes FSA to FSC. The inverter can be operated with or without maintenance switch. Thanks to the optional maintenance switch (this cannot be retrofitted), when service is required, the inverter can be simply disconnected from the line supply. Further, the G110D features an integrated braking chopper and an integrated class A EMC filter (acc. to EN 55011). Braking resistors, an Intelligent Operator Panel IOP Handheld, a local manual control including key switch, a memory card, a card holder for the memory card, etc. are additionally available. SINAMICS – the integrated drive family for every field of application.

Параметры

Width 445.0
Height 210.0
Depth 240.0
With control unit -
Number of digital inputs 4
Number of digital outputs -
Number of analogue inputs 1
Number of analogue outputs -
Supporting protocol for LON Нет
Number of HW-interfaces industrial Ethernet 0
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 0
Number of HW-interfaces USB 1
Number of HW-interfaces parallel 0
Number of HW-interfaces other 0
With optical interface Да
Supporting protocol for TCP/IP Нет
Supporting protocol for ASI Да
Supporting protocol for PROFIBUS Нет
Supporting protocol for CAN Нет
Supporting protocol for INTERBUS Нет
Supporting protocol for KNX Нет
Supporting protocol for MODBUS Нет
Supporting protocol for Data-Highway Нет
Supporting protocol for DeviceNet Нет
Supporting protocol for SUCONET Нет
Supporting protocol for other bus systems Нет
Degree of protection (IP) IP65
With PC connection Да
Supporting protocol for SERCOS Нет
Supporting protocol for INTERBUS-Safety Нет
Mains voltage 380
Mains frequency 50/60 Hz
4-quadrant operation possible Да
Number of interfaces PROFINET 0
Type of converter U converter
Number of phases output 3
Number of phases input 3
Integrated breaking resistance Да
Application in industrial area permitted Да
Application in domestic- and commercial area permitted Нет
Max. output frequency 650
Max. output at linear load at rated output voltage 7.5
Max. output at quadratic load at rated output voltage -
Relative symmetric net voltage tolerance -10
Relative symmetric net frequency tolerance -5
Supporting protocol for AS-Interface Safety at Work Нет
Supporting protocol for DeviceNet Safety Нет
Supporting protocol for EtherNet/IP Нет
Supporting protocol for Foundation Fieldbus Нет
Supporting protocol for PROFINET CBA Нет
Supporting protocol for PROFINET IO Нет
Supporting protocol for PROFIsafe Нет
Supporting protocol for SafetyBUS p Нет
Max. output voltage -
Nominal output current I2N 19
Supporting protocol for BACnet -
Degree of protection (NEMA) -