SINAMICS CU240E-2 PN

SINAMICS CU240E-2 PN. 6SL32440BB121FA0
419.51€
Включая НДС
Артикул: 6SL3244-0BB12-1FA0
SINAMICS G120 Управл. модуль CU240E-2 PN E-TYPE SAFETY Встр. STO PROFINET 6DI, 3DO, 2AI, 2AO, MAX 1F-DI PTC/KTY интерфейс USB- и SD/MMC-заглушка, IP20 Темп. окр. среды 0 +50С без Силового модуля и Панели оператора Control Unit SINAMICS CU240E-2 PN Control Unit for standard applications in general machinery construction for modular SINAMICS G120 inverters. The CU240E-2 Control Unit is part of the modular SINAMICS G120 inverter (comprising power unit, control unit, operator panel). The control unit is designed for all of the usual applications with U/f or vector control. These include encoderless basic applications in general machinery construction, for example. The CU240E-2 is equipped as standard with the integrated Safe Torque Off (STO) safety function. Further, the control unit has the integrated SS1, SLS, SDI and SSM safety functions, allowing it to address a wide range of applications. The CU240E-2 Control Unit controls and monitors the power unit (Power Module) and the connected motor several control modes can be selected. It facilitates communication to a local or central control system as well as to the monitoring equipment – and is used to connect all process-related auxiliary equipment and external components (sensors, valves, contactors, etc.) The I/O interface, the fieldbus interfaces and the additional software functions optimally support its use in general machinery construction. For intuitive series commissioning, a card slot is provided for cloning parameters sets. The communication interface of the inverter is defined when selecting the CU240E-2. The following integrated communication versions are available: CU240E-2 with USS and Modbus RTU protocols, CU240E-2 DP PROFIBUS and CU240E-2 PN PROFINET, EtherNet/IP. The Control Unit can be operated with the following SINAMICS power units: PM240-2 (0.55 kW to 132 kW) and PM240 (up to 250 kW). SINAMICS - simply my drive!

Параметры

Width 73.0
Height 199.0
Depth 46.0
With control unit -
Number of digital inputs 6
Number of digital outputs 3
Number of analogue inputs 2
Number of analogue outputs 2
Supporting protocol for LON Нет
Number of HW-interfaces industrial Ethernet 2
Number of HW-interfaces RS-232 1
Number of HW-interfaces RS-422 0
Number of HW-interfaces RS-485 0
Number of HW-interfaces serial TTY 4
Number of HW-interfaces USB 1
Number of HW-interfaces parallel 0
Number of HW-interfaces other -
With optical interface Нет
Supporting protocol for TCP/IP Да
Supporting protocol for ASI Нет
Supporting protocol for PROFIBUS Нет
Supporting protocol for CAN Нет
Supporting protocol for INTERBUS Нет
Supporting protocol for KNX Нет
Supporting protocol for MODBUS Нет
Supporting protocol for Data-Highway Нет
Supporting protocol for DeviceNet Нет
Supporting protocol for SUCONET Нет
Supporting protocol for other bus systems Нет
Degree of protection (IP) -
With PC connection Да
Supporting protocol for SERCOS Нет
Supporting protocol for INTERBUS-Safety Нет
Mains voltage -
Mains frequency -99999
4-quadrant operation possible -
Number of interfaces PROFINET 2
Type of converter -
Number of phases output -
Number of phases input Other
Integrated breaking resistance -
Application in industrial area permitted -
Application in domestic- and commercial area permitted -
Max. output frequency -
Max. output at linear load at rated output voltage -
Max. output at quadratic load at rated output voltage -
Relative symmetric net voltage tolerance -
Relative symmetric net frequency tolerance -
Supporting protocol for AS-Interface Safety at Work Нет
Supporting protocol for DeviceNet Safety Нет
Supporting protocol for EtherNet/IP Да
Supporting protocol for Foundation Fieldbus Нет
Supporting protocol for PROFINET CBA Нет
Supporting protocol for PROFINET IO Нет
Supporting protocol for PROFIsafe Да
Supporting protocol for SafetyBUS p Нет
Max. output voltage -
Nominal output current I2N -
Supporting protocol for BACnet Нет
Degree of protection (NEMA) 1