SINAMICS PM240P-2, IP20 / UL open type, FSD, 380-480 V 3 AC, 22,00 kW
2 762.14€
Включая НДС
Артикул: 6SL3210-1RE24-5UL0
SINAMICS G120 Силовой модуль PM240P-2 без фильтра ЭМС. Питание 3AC380-480В +10/-20% 47-63Гц, высокая перегрузка: 18,5кВт (150% 60с, далее 100% 240с) температура окружающей среды: от -20 до +50 градусов C (HO) низкая перегрузка: 22кВт (135% 3с, 110% 57с, 100% 240с) температура окружающей среды: от -20 до +40 градусов C (LO). Габаритные размеры: 472 X 200 X 237 (ВхШхГ), типоразмер: FSD. Степень защиты IP20. Без Управляющего модуля и без панели оператора. Совместим с Управляющими модулями, которые имеют версию прошивки не ниже V4.7 SP6 HF1. Power Modules SINAMICS PM240P-2 Power Module - the specialist for pumps, fans and compressors for the SINAMICS G120P inverter. A functional SINAMICS G120P inverter is created by teaming up the SINAMICS power unit with a matching CU230P-2 Control Unit and an IOP (Intelligent Operator Panel) or Basic Operator Panel (BOP-2) – or optionally a blanking cover. Thanks to the integrated Safety functions (Safe TorqueOff / Safe Stop 1) the power unit conforms to the highest safety level. Can be used in harsh environmental conditions as a result of the high degree of protection (IP55). The integrated DC link inductor ensures that savings are possible due to greater energy efficiency with a higher output voltage. The PM240P-2 power unit with IP55 protection is available for the power range from 11 kW to 132 kW and in three frame sizes ranging from FSD to FSF. It covers a voltage range from 380 V to 690 V. SINAMICS – the seamless drive family for every application area.
Параметры
Width | 200.0 |
Height | 472.0 |
Depth | 237.0 |
With control unit | - |
Number of digital inputs | - |
Number of digital outputs | - |
Number of analogue inputs | - |
Number of analogue outputs | - |
Supporting protocol for LON | - |
Number of HW-interfaces industrial Ethernet | - |
Number of HW-interfaces RS-232 | - |
Number of HW-interfaces RS-422 | - |
Number of HW-interfaces RS-485 | - |
Number of HW-interfaces serial TTY | - |
Number of HW-interfaces USB | - |
Number of HW-interfaces parallel | - |
Number of HW-interfaces other | - |
With optical interface | - |
Supporting protocol for TCP/IP | - |
Supporting protocol for ASI | - |
Supporting protocol for PROFIBUS | - |
Supporting protocol for CAN | - |
Supporting protocol for INTERBUS | - |
Supporting protocol for KNX | - |
Supporting protocol for MODBUS | - |
Supporting protocol for Data-Highway | - |
Supporting protocol for DeviceNet | - |
Supporting protocol for SUCONET | - |
Supporting protocol for other bus systems | - |
Degree of protection (IP) | IP20 |
With PC connection | - |
Supporting protocol for SERCOS | - |
Supporting protocol for INTERBUS-Safety | - |
Mains voltage | 380 |
Mains frequency | 50/60 Hz |
4-quadrant operation possible | Нет |
Number of interfaces PROFINET | - |
Type of converter | U converter |
Number of phases output | 3 |
Number of phases input | 3 |
Integrated breaking resistance | Нет |
Application in industrial area permitted | Нет |
Application in domestic- and commercial area permitted | Нет |
Max. output frequency | 550 |
Max. output at linear load at rated output voltage | 18.5 |
Max. output at quadratic load at rated output voltage | 22.0 |
Relative symmetric net voltage tolerance | -10 |
Relative symmetric net frequency tolerance | 5 |
Supporting protocol for AS-Interface Safety at Work | - |
Supporting protocol for DeviceNet Safety | - |
Supporting protocol for EtherNet/IP | - |
Supporting protocol for Foundation Fieldbus | - |
Supporting protocol for PROFINET CBA | - |
Supporting protocol for PROFINET IO | - |
Supporting protocol for PROFIsafe | - |
Supporting protocol for SafetyBUS p | - |
Max. output voltage | - |
Nominal output current I2N | 45 |
Supporting protocol for BACnet | - |
Degree of protection (NEMA) | - |