Current monitoring relay for IO-Link S0. 3RR24422AA40
204.79€
Включая НДС
Артикул: 3RR2442-2AA40
РЕЛЕ КОНТРОЛЯ ТОКА ДЛЯ IO-LINK, ДЛЯ МОНТАЖА НА КОНТАКТОР 3RT2, ТИПОРАЗМЕР S0, ЦИФРОВАЯ РЕГУЛИРОВКА ПАРАМЕТРОВ, С ЖКД, КОНТРОЛЬ ПОЛНОГО ТОКА/АКТИВНОЙ СОСТАВЛЯЮЩЕЙ ТОКА 4 - 40A, 20-400 ГЦ, 3-Ф. ПИТАНИЕ 24 V DC, 1 П КОНТАКТ, КОНТРОЛЬ ПРЕВЫШЕНИЯ/ ПОНИЖЕНИЯ ТОКА, ВЫПАДЕНИЯ ФАЗЫ, ОБРЫВА ПРОВОДА, ЧЕРЕДОВАНИЯ ФАЗ, БЛОКИРОВКИ РОТОРА ЭЛЕКТРОДВИГАТЕЛЯ, КОНТРОЛЬ ТОКА УТЕЧКИБ, СЧЕТЧИК ЧАСОВ РАБОТЫ , ПРЕДУПРЕЖДЕНИЕ И СИГНАЛИЗАЦИЯ ПРИ ДОСТИЖЕНИИ ПОРОГОВЫХ ЗНАЧЕНИЙ, ЗАДЕРЖКА ВКЛ. 0-999.9 С., ЗАДЕРЖКА ОТКЛ 0-999.9С, ЗАДЕРЖКА ПЕРЕЗАПУСКА 0-999.9 МИН, ПРУЖИННЫЕ КЛЕММЫ Monitoring relays SIRIUS 3RR2 for plugging into SIRIUS 3RT2 contactors or for stand-alone installation for multi-phase current monitoring of the entire plant or of the driven process. The reliable monitoring for cable break, phase failure / sequence, fault current, motor blocking etc. ensures increased plant availability. Actual value displays, status messages and clear error messages permit fast and reliable diagnostics. The connection to the control via IO-Link is also possible. You also save money, as only one device is needed to monitor a motor along the entire torque curve and no separate current converter is required either. Thanks to the direct attachment to the 3RT2 contactors there is no additional wiring expense in the main circuit. You also benefit from the wide-range power supplies for global use. Analogically adjustable, 2-phase versions and digitally adjustable, 3-phase versions (with or without IO-Link) are available, each in three sizes with different current measuring ranges, with two different supply voltages and two types of connection. Matching holders are available for the stand-alone installation of the 3RR2 monitoring relays. SIRIUS relays - one range for every application.

Параметры

Width 45.0
Height 109.0
Depth 92.0
Current measurement range 4.0
External current transformer Нет
With detachable clamps Да
Single-phase hysteresis possible Нет
Three-phase hysteresis possible Нет
Single-phase under current possible Нет
Three-phase under current possible Да
Single-phase over current possible Нет
Three-phase over current possible Да
Contains function DC-voltage under current Нет
Contains function DC-voltage over current Нет
Function DC-current hysteresis Нет
Type of electric connection Spring clamp connection
Rated control supply voltage Us at AC 50HZ -
Rated control supply voltage Us at AC 60HZ -
Rated control supply voltage Us at DC 24
Max. permitted delay-on energization time 999.9
Min. adjustable delay-on energization time 0
Max. permitted off-delay time 999.9
Min. adjustable off-delay time 0
Voltage type for actuating DC
Number of contacts as normally closed contact -
Number of contacts as normally open contact -
Number of contacts as change-over contact -