SIRIUS, Extension module 3RK32 for Modular Safety System 3RK3 2/4 F-DI
294.12€
Включая НДС
Артикул: 3RK3231-1AA10
SIRIUS, EXPANSION МОДУЛЬ 3RK32 ДЛЯ MODULAR SAFETY SYSTEM 3RK3 2/4 F-DI, 2 F-DO, 24V DC/1.5A PARAMETERIZABLE VIA SW MSS ES WIDTH 22.5MM ВИНТОВЫЕ КЛЕММЫ UP ДО CATEGORY 4 (EN954-1) UP ДО SIL3 (IEC 61508) UP TO PERFORMAНЗE LEVEL E (ISO 13849-1)
Параметры
| Width | 22.5 |
| Model | - |
| Height | 102.0 |
| Depth | 124.0 |
| Release-delay | - |
| With approval according to UL | Да |
| With detachable clamps | Да |
| With start input | - |
| With feedback circuit | - |
| Number of outputs, safety related, undelayed, with contact | 0 |
| Number of outputs, safety related, delayed, with contact | - |
| Number of outputs, safety related, undelayed, semiconductors | 2 |
| Number of outputs, safety related, delayed, semiconductors | - |
| Number of outputs, signalling function, undelayed, with contact | - |
| Number of outputs, signalling function, delayed, with contact | - |
| Number of outputs, signalling function, undelayed, semiconductors | - |
| Number of outputs, signalling function, delayed, semiconductors | - |
| Type of electric connection | Screw connection |
| Rail mounting possible | Нет |
| Rated control supply voltage Us at AC 50HZ | - |
| Rated control supply voltage Us at AC 60HZ | - |
| Rated control supply voltage Us at DC | 24 |
| With muting function | Нет |
| Type of safety acc. IEC 61496-1 | - |
| With approval for TÜV | Да |
| With approval for BG BIA | - |
| Category according to EN 954-1 | 4 |
| Suitable for monitoring of magnetic switches | Да |
| Suitable for monitoring of proximity switches | Да |
| Suitable for monitoring of emergency-stop circuits | Да |
| Suitable for monitoring of optoelectronic protection equipment | Да |
| Suitable for monitoring of position switches | Да |
| Suitable for monitoring of tactile sensors | Да |
| Suitable for monitoring of valves | Да |
| Performance level acc. EN ISO 13849-1 | - |
| Stop category acc. IEC 60204 | Other |
| Voltage type for actuating | DC |
| Evaluation inputs | - |
| SIL according to IEC 61508 | 3 |